Skip to Content Facebook Feature Image

Two new Legionnaires' disease cases reported; public urged to maintain water systems and observe health precautions

HK

Two new Legionnaires' disease cases reported; public urged to maintain water systems and observe health precautions
HK

HK

Two new Legionnaires' disease cases reported; public urged to maintain water systems and observe health precautions

2025-11-03 20:01 Last Updated At:11-06 17:06

DH announces latest situation of Legionnaires' disease cases

The Centre for Health Protection (CHP) of the Department of Health today (November 3) reported the latest number of Legionnaires' disease (LD) cases, and reminded the public of the importance of using and maintaining properly designed man-made water systems, adding that susceptible groups should strictly observe relevant precautions.

From October 26 to November 1, the CHP recorded two LD cases. Both patients involved had underlying illnesses. The details of the cases are as follows:

  • A 70-year-old male patient living in Kwun Tong District, classified as a community-acquired case.

  • A 69-year-old male patient who travelled to the Mainland during the incubation period, classified as an imported case.

The CHP is conducting epidemiological investigations to identify potential sources of infection and high-risk exposure. Initial investigations revealed that these are sporadic cases. No epidemiological linkages have been established between these two cases and other confirmed cases previously recorded in Hong Kong.

As of November 1, 137 LD cases had been recorded this year. In 2024 and 2023, there were 135 and 121 LD cases respectively.

Men, people aged over 50, smokers, alcoholics and persons with weakened immunity are more susceptible to LD. Some situations may also increase the risk of infection, including poor maintenance of water systems; living in areas with old water systems, cooling towers or fountains; using electric water heaters, whirlpools and spas or hot water spring spas; and recent stays in hotels or vessels.

Legionellae are found in various environmental settings and grow well in warm water (20 to 45 degrees Celsius). They can be found in aqueous environments such as water tanks, hot and cold water systems, cooling towers, whirlpools and spas, water fountains and home apparatus that support breathing. People may become infected when they breathe in contaminated droplets (aerosols) and mist generated by artificial water systems, or when handling garden soil, compost and potting mixes.

Immunocompromised persons should:

  • Use sterile or boiled water for drinking, tooth brushing and mouth rinsing;

  • Avoid using humidifiers, or other mist- or aerosol-generating devices; and

  • If using humidifiers, or other mist- or aerosol-generating devices, fill the water tank with only sterile or cooled freshly boiled water, and not water directly from the tap. Also, clean and maintain humidifiers/devices regularly according to manufacturers' instructions. Never leave stagnant water in a humidifier/device. Empty the water tank, wipe all surfaces dry, and change the water daily.

​The public should observe the health advice below:

  • Observe personal hygiene;

  • Do not smoke and avoid alcohol consumption;

  • Strainers in water taps and shower heads should be inspected, cleaned, descaled and disinfected regularly or at a frequency recommended by the manufacturer;

  • If a fresh-water plumbing system is properly maintained, it is not necessary to install domestic water filters. Use of water filters is not encouraged as clogging occurs easily, which can promote growth of micro-organisms. In case water filters are used, the pore size should be 0.2 micrometres (µm) and the filter needs to be changed periodically according to the manufacturer's recommendations;

  • Drain and clean water tanks of buildings at least quarterly;

  • Drain or purge for at least one minute infrequently used water outlets (e.g. water taps, shower heads and hot water outlets) and stagnant points of the pipework weekly or before use;

  • Seek and follow doctors' professional advice regarding the use and maintenance of home respiratory devices and use only sterile water (not distilled or tap water) to clean and fill the reservoir. Clean and maintain the device regularly according to the manufacturer's instructions. After cleaning/disinfection, rinse the device with sterile water, cooled freshly boiled water or water filtered with 0.2 µm filters. Never leave stagnant water in the device. Empty the water tank, keep all surfaces dry, and change the water daily; and

  • When handling garden soil, compost and potting mixes:

  • Wear gloves and a face mask;

  • Water gardens and compost gently using low pressure;

  • Open composted potting mixes slowly and make sure the opening is directed away from the face;

  • Wet the soil to reduce dust when potting plants; and

  • Avoid working in poorly ventilated places such as enclosed greenhouses.

​​ The public may visit the CHP'sLD page, theCode of Practice for Prevention of LDand theHousekeeping Guidelines for Cold and Hot Water Systems for Building Managementof the Prevention of LD Committee, and the CHP'srisk-based strategyfor prevention and control of LD.

Source: AI-found images

Source: AI-found images

Scam alert related to banks

The following is issued on behalf of the Hong Kong Monetary Authority:

The Hong Kong Monetary Authority (HKMA) wishes to alert members of the public to the press releases issued by the banks listed below relating to fraudulent websites, internet banking login screens, phishing emails or other scams, which have been reported to the HKMA. Hyperlinks to the press releases are available on theHKMA website.

Bank

Type of scam

The Bank of East Asia, Limited

Fraudulent websites, internet banking login screens and phishing email

Shanghai Commercial Bank Limited

Fraudulent website and internet banking login screen

OCBC Bank (Hong Kong) Limited

Fraudulent website and internet banking login screen

Chong Hing Bank Limited

Fraudulent website and internet banking login screen

Chiyu Banking Corporation Limited

Fraudulent websites and internet banking login screens

The HKMA wishes to remind the public that banks will not send SMS or emails with embedded hyperlinks which direct them to the banks' websites to carry out transactions. They will not ask customers for sensitive information, such as login passwords or one-time password, by phone, email or SMS (including via embedded hyperlinks).

Anyone who has provided his or her personal information, or who has conducted any financial transactions, through or in response to the scams concerned, should contact the relevant bank with the information provided in the corresponding press release, and report the matter to the Crime Wing Information Centre of the Hong Kong Police Force at 2860 5012.

Source: AI-found images

Source: AI-found images

Recommended Articles